J1_Shafted_Banner

HP58 | PRODUCT TECHNICAL SPECIFICATIONS AND DOWNLOADS

HP58_Noncontact_Rotary

58mm Full Size IP69K Non-contact Rotary

Absolute Single-turn, Multi-turn or Incremental Encoder

  • Patented true non-contact position sensing
  • - 0.5" (12mm) gap between sensor and application
  • - 0.10" (2.5mm) center alignment
  • - 30° planar tilt
  • Totally sealed IP69K (connector dependent)
  • LED indicators for power and output feedback
  • Incremental or Absolute position
  • Outputs: Quadrature, Step and Direction, SSI, PWM, Analog, Modicon MODBUS, & J1939 Can Bus
  • Detects rotation through non-ferrous barriers; Special applications include use in explosion proof housing, high PSI zone separation, and enclosed rotational measurement

Browse the Quick View section to find instant specifications, order information, and dimensioned drawings. Information found in the Quick View is available in PDF format for direct download.

Technical data and dimensioned drawings
found in quick view tabs can be downloaded by clicking the PDF page icons below under Download Fast Links. Data sheets and downloads can also be found on the Data & Downloads section of the Joral, LLC webpage.

Quick View | SELECT TABS BELOW TO QUICK VIEW TECH ITEMS

Operating Characteristics | ELECTRICAL, MECHANICAL AND ENVIRONMENTAL SPECS

  • Outputs A - PPR - SEPP Incremental 13 bit Quadrature w/ Single Ended Output | A B Z
    A - PPR - DIPP Incremental 13 bit Quadrature w/ Differential Output | A B Z & A' B' Z'
    A - 1939 J1939 13 bit @ 1000 positions (8192 positions max)
    A - MOD1 Modicon MODBUS @ 8192 positions
    B - PWM PWM absolute position
    A - SSI1 SSI absolute position @ 8192 positions
    V1 Voltage Out / 5 VDC IN, 0-5 VDC OUT (code V3 for 2x redundant output)
    V2 Voltage Out / 6-36 VDC IN, 0-5 VDC OUT
    I1 Current Out / 0-24 VDC IN, 4-20 mA OUT (code I1 for 2x redundant output)
    Input Power 6 to 30 VDC at approx 60mA max, not including output loads
    Electrical Protection Over-voltage, reserve-voltage, output short circuit protected
    LED Indicators Power and output channels
    Connections Terminal Plug, M8, M12, M12 Pigtail, Flying Lead Cable, Shielded Flying Lead, or Deutsch - 4 or 6 pin
    Resolution 0.3°
    Repeatability 0.30%
    Nonlinearity <1%
    Housing Diameter 58mm
    Housing Material HP58 Black Delrin™ (standard) or White Delrin™; HP58SE Red Aluminum
    Housing Height 0.75" (19mm) body; 1.5" (38.1mm) w/ M12 connector
    Mounting 60.128 Mounting holes
    Weight 2.6 oz
    Magnet/sensor gap* Standard 0.5" (12mm) (Max w/ custom mag assembly up to 1" [30mm])
    Rated planer tilt/axial gap* Planar 30° (Max 45°) / Axial 0.1" (2.5mm)(Max 0.16" [4mm])
    *Non-contact tolerances rated using MAGH-RING 1/4x20 magnet accessory.
    Speed 3000 RPM max
    Operating Temperature -30° to +80° C
    Storage Temperature -40° to +90° C
    Humidity 100%
    Shock 400g/6ms (MIL STD 202)
    Vibration 5 to 3000 Hz, 20g (MIL STD 202)
    Protection Class IP69K (connection dependant)

Ordering Guide | PART NUMBER BUILD CHART AND SPECIAL P/N INFORMATION


To build Joral P/N first start with Housing Style [Code 1], MagElec or Output [Code 2], and Connection Code [Code 3].

Add Special Codes or Modifiers [code 4] to the end of the Joral P/N. If no unique modifier is used sensor is built to standard specifications. Unique modifiers override standard specification.

It does not matter if modifier listed is same as standard build (such as listing redundant modifier 51, red aluminum, for PE30; example PE30-1939-M12-51).

P/N
Examples

  • Quadrature: [HOUSING]-[BIT CODE]-[PPR]-[DRIVER]-[CONN.]-[MODIFIERS]
  • J1939: [HOUSING]-A-J1939-[CONN.]-[MODIFIERS]
  • Voltage: [HOUSING]-[MAGELEC]-[ANGLE RANGE]-[VOLTAGE RANGE]-[...]-[...]

Click table to enlarge view

Click here to close

Enlarged View |Maximize browser window for best viewing results

Code 1:
Housing Style
Code 2:
MagElec (Sensor Output)
Code 3:
Connection
Code 4:
Special Codes
HP58

HP58 material black Delrin™, connector orientation BACK EXIT standard.
To designate SIDE EXIT CONN use special code 31 (side exit for HP58 CABLE ONLY).

 

A-[PPR]-SEPP 13 bit single ended quadrature - A B Z TRM Pluggable terminal block 31 1/4" (0.250") w/ flat
A-[PPR]-DIPP 13 bit differential quad - A B Z, A'B'Z' INS Wire insertion terminal 32 10mm round
A-1939 13 bit J1939 @ 1000 positions M8 M8 male 33 3/8" slotted
B-PWM Absolute position PWM M12 M12 Male 50 Extended 3/8" slotted
A-MOD1 13 bit MODBUS @ 8192 positions M12P M2 male on 18" pigtail 51 Extended 6mm w/ flat
HP58SE

HP58SE made out of Red Aluminum, connector orientation BACK EXIT standard.
To designate SIDE EXIT CONN use special code 31

A-SSI Absolute SSI @8192 positions CXX Flying lead cable (XX=inches) 71 6mm w/ flat
V1 5 VDC IN,
0-5 VDC out
SCXX Shielded cable (XX=inches) 72 Red aluminum
V2 6-36 VDC IN,
0-5 VDC out
CSP Cable with custom ends 90 13 bit @ 8192 counts per rotation (typical J1939 option)
V3 V1 Ranges, 2x Redunant Output DE4 DT04 - 4 pin male Deutsch
* More outputs and connection options available, contact Joral if desired configuration
is not listed
I1 0-24 VDC IN,
4-20 mA out
DE6 DT04 - 6 pin male Deutsch 91 13 bit @ 1000 counts per rotation (typical MODBUS opt.)
I2 I2 Ranges, 2x Redundant Output  
   
Click here to close

Enlarged View |Maximize browser window for best viewing results

Special Part Number Information
CODE 1: Housing Style
Modifier 31 - For side exit connector on HP58 and HP58SE add 31 to end of Joral P/N
HP58
- Handles all back exit connections and CABLE ONLY side exit connections (M12P, CXX, SCXX, DE4, & DE6)
HP58SE - Handles ALL back exit connections (including M12 leaded side exit)
CODE 2: MagElec
A - _ _ _ _ - SEPP
A - _ _ _ _ - DIPP


  • Enter Quadrature PPR
    in place of _ _ _ _
  • A = 13 bit PPR
  • Available 13 bit PPR:
    0008,0010,0016,0020,
    0025,0032,0040,0050,
    0064,0080,0100,0125,
    0128,0200,0250,0256,
    0400,0500,1024,2048
A - 1939

  • Standard J1939
    outputis 1000
    positions
  • A = 13 bit
  • Modifier 90 -
    for 8192 positions
    (max resolution)
    add code 90
    to end of
    HP58 P/N
A - MOD1

  • Standard MODBUS
    outputis 8192
    positions
  • A = 13 bit
  • Modifier 91 -
    for 1000 positions
    (max resolution)
    add code 91
    to end of
    HP58 P/N
V1, V2 and I1
(Analog MagElec P/N Guide)

  • First select MagElec Code, then Angle Range, Voltage Range, and Signal Direction
  • Mag Codes: V1, V2, I1
  • Angle Ranges (A1-A2): 0-360° to 1° increments
  • Voltage Ranges (VR1-VR2): Selectable upper and lower limits, 0.1 unit increments
  • PART NUMBER FORMULA -
    (MagElec)-(A1-A2)-(VR1-VR2)-(CW/CCW)
  • EXACT V1, V2, I1 EXAMPLES
    (MagElec)-(A1-A2)-(VR1-VR2)-(CW or CCW)
CODE 3: Connections
  • All Outputs, All Connections - Connector exit standard is BACK EXIT (sensor epoxy side) for housing HP58 and HP58SE (for side exit use modifier 31)
  • J1939 Output - Addressing via varying value resistor in connection requires at least five conductors
    (M12, DE6, and Cables are J1939 addressing compatible)
  • All Outputs w/ Deutsch = DE4 and DE6 connection Deutsch connectors add $20 to HP58 list
Click here to close

Enlarged View |Maximize browser window for best viewing results

  • HP58 Non-contact |FULL SIZE DRAWING - FOR PRINT DOWNLOAD DWG FLIER OR TECH CUT PDF

  • HP58 Non-contact Rotary Position Sensor Dimensioned Drawing
Click here to close

Enlarged View |Maximize browser window for best viewing results

  • HP58SE Non-contact |FULL SIZE DRAWING - FOR PRINT DOWNLOAD DWG FLIER OR TECH CUT PDF

  • HP58SE Non-contact Rotary Position Sensor Dimensioned Drawing